Boiler Water Treatment Chemicals
Boiler Treatment
Industrial boilers are widely used in process and industrial heating systems. Like any equipment, periodical maintenance and cleaning of boilers is crucial. Boiler water treatment is basically done to keep them free from scale and corrosion, enable continuous heat exchange, and produce and maintain high quality of steam. External water treatment can be done in many ways such as softening, de-aeration, ion-exchange, evaporation, and chemical treatment. There are many chemical providers in the market. If you looking for boiler water treatment chemicals for boilers at your plant, ensure you buy high-quality products that keep your boilers free from scale, corrosion and premature failure, then consider Aztec H2O Services your reliable supplier of boiler water treatment chemicals.
Boiler maintenance is critical to maintaining the performance of the system. It only takes a small amount of scale on the heat transfer surface to significantly reduce the boiler’s efficiency. This translates into a very high cost of operation. By using our boiler water treatment chemicals, you can ensure the highest degree of boiler efficiency and reduced maintenance costs. Contact the experts at Cannon Water Technology, Inc. We are always ready to help our clients setup the best water treatment program possible.
Aztec H2O Services provides you a variety of chemicals and help you select the ones that suit your requirements and budget. Here, we have listed a few types of chemicals that fulfill varied purposes:
Industrial boilers are widely used in process and industrial heating systems. Like any equipment, periodical maintenance and cleaning of boilers is crucial. Boiler water treatment is basically done to keep them free from scale and corrosion, enable continuous heat exchange, and produce and maintain high quality of steam. External water treatment can be done in many ways such as softening, de-aeration, ion-exchange, evaporation, and chemical treatment. There are many chemical providers in the market. If you looking for boiler water treatment chemicals for boilers at your plant, ensure you buy high-quality products that keep your boilers free from scale, corrosion and premature failure, then consider Aztec H2O Services your reliable supplier of boiler water treatment chemicals.
Boiler maintenance is critical to maintaining the performance of the system. It only takes a small amount of scale on the heat transfer surface to significantly reduce the boiler’s efficiency. This translates into a very high cost of operation. By using our boiler water treatment chemicals, you can ensure the highest degree of boiler efficiency and reduced maintenance costs. Contact the experts at Cannon Water Technology, Inc. We are always ready to help our clients setup the best water treatment program possible.
Aztec H2O Services provides you a variety of chemicals and help you select the ones that suit your requirements and budget. Here, we have listed a few types of chemicals that fulfill varied purposes:
- All-in-One: These chemicals are suitable for steam boilers where more than 80% of steam is condensed back to water. Usually, they are the right mix of nitrite, borax, azole, and polymeric organic dispersants. They protect iron, copper, and brass boilers that operate in the pressure range below 300 psi.
- Corrosion Inhibitors: These chemicals protect the central heating systems from corrosion and lime scale. They are heavy duty rust cleaners that use the TripleTech™ anti-corrosion technology.
- Oxygen Scavengers and Alkalinity Boosters: These chemicals are suitable for boilers that operate in the pressure range below 300 psi. It is a perfect mix of alkalinity boosters, sulfite oxygen scavengers, and polymeric organic dispersants. It complies with the FDA/USDA guidelines.
AZ-BW-409 All-In-One Steam Boiler Treatment
Product Description
Product Description
- Designed for steam boilers where more than 80% of the steam condenses into water and returns to the boiler as condensate. Easy to apply. Easy to test. Can be shipped UPS Ground in 5-gallon containers.
- Balanced blend of nitrite, borax, azole and polymeric organic dispersants. Protects iron, copper and brass metals.
- Has dedicated iron oxide dispersants to retard rust deposits.
- Contains a steam line treatment that neutralizes low acidic pH in the condensate return lines.
- Can be used on steam boilers that have hard water makeup, however, for best results soften makeup water.
- AZ-BW-409 is intended for use in boilers operating in the low and medium pressure range below 300 psi.
- This boiler chemistry has been successfully used in schools, high-rise buildings and apartment buildings where steam is used for heating and there is less than 20% loss of condensate.
- AZ- BW-409 can be fed by hand or with a chemical metering pump connected to the feed water storage tank or feed water line. If possible, interlock the chemical metering pump to the boiler feed water pump so that chemical is fed in proportion to load. Feed one gallon per 100 gallons of boiler water.
- Use Nitrite Test Kit P.N.# CNTK3300-Z to test for AZ-BW-409. The recommended test range is 800 - 1500 ppm as Sodium Nitrite.
AZ-BW-103 All-In-One Steam Boiler Treatment
Oxygen Scavenger - Deposit Control - Alkalinity Control - Steam Line Protection
Product Description
Oxygen Scavenger - Deposit Control - Alkalinity Control - Steam Line Protection
Product Description
- Concentrated: 14 - 21 ounces treats 1000 gallons of feed water.
- Balanced blend of alkalinity boosters, sulfite oxygen scavengers and polymeric organic dispersants.
- Has a dedicated iron oxide dispersants to retard rust deposits.
- Contains a steam line treatment that neutralizes low acidic pH in the condensate return lines.
- Can be used on steam boilers that have hard water makeup, however, for best results soften makeup water.
- Ingredients in AZ-BW-103 meet FDA/USDA guidelines for use in treating boilers where the steam produced may contact edible food products.
- AZ-BW-103 is intended for use in boilers operating in the low and medium pressure range below 300 psi.
- AZ-BW-103 should be fed with a chemical metering pump into the feed water storage tank or feed water line. If possible, interlock the chemical metering pump to the boiler feed water pump so that chemical is fed in proportion to load.
- Use Sulfite Test Kit P.N.# CNTK3502-Z to test for AZ-BW-103. The recommended test range is 30 - 60 ppm as Sulfite.
AZ-BW-730 All-In-One Steam Boiler Treatment
Oxygen Scavenger - Deposit Control - Alkalinity Control - Steam Line Protection
Product Description
Oxygen Scavenger - Deposit Control - Alkalinity Control - Steam Line Protection
Product Description
- Concentrated: 14 - 21 ounces treats 1000 gallons of feed water.
- Balanced blend of alkalinity boosters, sulfite oxygen scavengers and polymeric organic dispersants.
- Has dedicated iron oxide dispersants to retard rust deposits.
- Does not contain a steam line treatment.
- Can be used on steam boilers that have hard water makeup, however, for best results soften makeup water.
- Ingredients in AZ-BW-730 meet FDA/USDA guidelines for use in treating boilers where the steam produced may contact edible food products.
- AZ-BW-730 is intended for use in boilers operating in the low and medium pressure range below 300 psi.
- AZ-BW-730 should be fed with a chemical metering pump in to the feed water storage tank or feed water line. If possible, interlock the chemical metering pump to the boiler feed water pump so that chemical is fed in proportion to load.
- Use Sulfite Test Kit P.N.# CNTK3502-Z to test for AZ-BW-730. The recommended test range is 30 - 60 ppm as Sulfite.
AZ-PC-ECO-GREEN Pre-Clean Chemical
Safe to use, Protects While It Cleans Closed Loops, Boilers and Cooling Systems
Product Description
Safe to use, Protects While It Cleans Closed Loops, Boilers and Cooling Systems
Product Description
- Cleans while it protects closed hot and chill water loops, boilers and cooling towers.
- Functions by penetrating and reducing surface tension of dirt, mud, oil and rust deposits so that these deposits can be flushed out of closed loops, boilers and cooling systems.
- Helps remove dirt, oil, mill scale, rust and debris from new and old piping and heat exchanger surfaces.
- NOT Compatible with aluminum. Use Sentinel X400 for systems containing aluminum.
- Safe to use, environmentally friendly, can be flushed to sanitary sewers.
- Can be used in cooling towers as a pre-cleaning agent to help lift and remove deposits that are difficult to reach and physically remove.
- Mixes quickly in cold and hot water and is safer to use than TSP or caustic detergent cleaners.
- Especially effective in new construction piping to help remove cutting oils and flux from new piping. Not intended for use in potable domestic drinking water lines.
- Non hazardous, can be UPS shipped in 5-gallon containers
- ECO-Green - PreClean should be fed at a rate of 2 - 5 liquid ounces per 100 gallons of water in systems that are lightly fouled. For heavily fouled systems or new construction piping, use 12 ounces to 1-gallon per 100 gallons of water.
- Feed by hand, bypass feeder or chemical pump into the re-circulating water and allow to circulation for 6 -24 hours. After circulation thoroughly flush until the water is clear. Take precautions in heavily fouled systems where large amounts of dirt, scale and deposits may plug screens, small lines and heat exchangers.
- Heating the water will increase the cleaning action of ECO-Green - PreClean. Keep temperatures below 180 degrees Fahrenheit.
Sentinel Product Line - Scale & Corrosion Inhibitors
Sentinel X100 Corrosion Inhibitor for Central Heating Systems - Perfect for Aluminum Boilers and Heat Exchangers - 5 gallon pail
Sentinel X100 corrosion inhibitor for boilers provides protection for clean central heating systems against limescale and corrosion. Suitable for use in all types of indirect central heating systems to include aluminum heat exchangers. Sentinel X100 Scale and Corrosion Inhibitor Chemicals will extend the life of the hot water system, ensuring maximum efficiency of the boiler and minimizing fuel usage.
KEY FEATURES
Sentinel X100 treatment chemical is one of the only corrosion inhibitors that is safe to use on Aluminum Boilers and Heat Exchangers.
Limescale and corrosion are the two main causes of central heating inefficiency, leading to radiator cold spots, boiler inefficiency, a noisy system and a multitude of other problems. Once a system has been prepared using one of the cleaners from the Sentinel cleaning range, it should be protected with Sentinel X100 Inhibitor to prevent the occurrence of limescale build up or corrosion.
Sentinel X100 Inhibitor has TripleTech™ Anti-Corrosion Technology, a unique blend of heavy-duty specialist corrosion inhibitors. Since central heating systems are normally made up of a variety of metals, each of these specialist inhibitors provides protection for different metals for unrivalled performance in protecting multi-metal central heating systems.
Sentinel X100 corrosion inhibitor for boilers provides protection for clean central heating systems against limescale and corrosion. Suitable for use in all types of indirect central heating systems to include aluminum heat exchangers. Sentinel X100 Scale and Corrosion Inhibitor Chemicals will extend the life of the hot water system, ensuring maximum efficiency of the boiler and minimizing fuel usage.
KEY FEATURES
- Heavy duty rust inhibitor
- Protects against limescale and corrosion of boiler
- Energy Saving Trust Recommended
- TripleTech™ Anti-Corrosion Technology
- Suitable for all system metals including Aluminum Boilers and Heat Exchangers
- pH neutral formulation
- Ensures optimum system efficiency
- Suitable for hard, soft and artificially softened water
- Helps prevent the formation of hydrogen gas
- A simple test kit is available to check levels
Sentinel X100 treatment chemical is one of the only corrosion inhibitors that is safe to use on Aluminum Boilers and Heat Exchangers.
Limescale and corrosion are the two main causes of central heating inefficiency, leading to radiator cold spots, boiler inefficiency, a noisy system and a multitude of other problems. Once a system has been prepared using one of the cleaners from the Sentinel cleaning range, it should be protected with Sentinel X100 Inhibitor to prevent the occurrence of limescale build up or corrosion.
Sentinel X100 Inhibitor has TripleTech™ Anti-Corrosion Technology, a unique blend of heavy-duty specialist corrosion inhibitors. Since central heating systems are normally made up of a variety of metals, each of these specialist inhibitors provides protection for different metals for unrivalled performance in protecting multi-metal central heating systems.
Sentinel RAPID-DOSE X100RD Inhibitor
Sentinel X100 Rapid-Dose Inhibitor has been formulated as a multipurpose treatment to prevent sludge build-up over time in heating systems. Designed for easy dosing to the system quicker than ever, the Rapid-Dose Inhibitor efficaciously helps break down rust and minerals. It thus protects your heating system by preventing the rust build up inside your pipes, boilers, and radiators. Sentinel RAPID-DOSE X100RD Inhibitor keeps your system running longer with optimum performance. Ideal for use in all types of indirect heating systems, the X100RD Inhibitor prevents corrosion and limescale in steel, cast iron, copper, brass and aluminum. The product SKU is X100RD.
Specifications of Sentinel RAPID-DOSE X100RD Inhibitor
Sentinel RAPID-DOSE X100RD Inhibitor is compatible for use with several metal substrates. Featuring an aqueous solution of inorganic and organic corrosion and scale inhibitors, X100RD is the market leading inhibitor available in the following specifications.
Sentinel X100 Rapid-Dose Inhibitor has several proven features, making it a highly sought-after solution for central heating systems. It assures hands-free dosing for the most difficult to access systems, whilst guaranteeing speedy discharge into the system in just 30 seconds. The other noteworthy features of this general purpose corrosion treatment solution are;
Giving the assurance of enhanced scale and corrosion protection, Sentinel RAPID-DOSE X100RD Inhibitor finds immense applications like maintaining pipework systems and similar other equipment. A few other application areas include:
Sentinel X100 Rapid-Dose Inhibitor has been formulated as a multipurpose treatment to prevent sludge build-up over time in heating systems. Designed for easy dosing to the system quicker than ever, the Rapid-Dose Inhibitor efficaciously helps break down rust and minerals. It thus protects your heating system by preventing the rust build up inside your pipes, boilers, and radiators. Sentinel RAPID-DOSE X100RD Inhibitor keeps your system running longer with optimum performance. Ideal for use in all types of indirect heating systems, the X100RD Inhibitor prevents corrosion and limescale in steel, cast iron, copper, brass and aluminum. The product SKU is X100RD.
Specifications of Sentinel RAPID-DOSE X100RD Inhibitor
Sentinel RAPID-DOSE X100RD Inhibitor is compatible for use with several metal substrates. Featuring an aqueous solution of inorganic and organic corrosion and scale inhibitors, X100RD is the market leading inhibitor available in the following specifications.
- Weight: 1.5 LBS
- Appearance: Clear colorless to pale green or pale yellow liquid
- Specific gravity: 1.20 (20 degree Celsius)
- pH Concentrate; 6.5 approximately
- Freezing point: Minus 2.5 Degree Celsius
Sentinel X100 Rapid-Dose Inhibitor has several proven features, making it a highly sought-after solution for central heating systems. It assures hands-free dosing for the most difficult to access systems, whilst guaranteeing speedy discharge into the system in just 30 seconds. The other noteworthy features of this general purpose corrosion treatment solution are;
- Heavy duty rust inhibitor with TripleTech™ anti-corrosion technology ensures optimum system efficiency.
- This completely non-toxic and bio-degradable solution is suitable for all system metals.
- It has a twist and dose system, which is extremely simple to dose, and there is no need to de-pressurize or cool the system to initiate the discharge.
- This pH neutral formulation effectively removes sludge, limescale and other debris.
- This non-staining solution with multiple heavy-duty inhibitors and pH stabilizers prevents pin-holing.
- The solution is extremely easy and safe to handle, and there is no mess left out during dosing.
- Suitable for hard, soft and artificially softened water, the solution helps prevent hydrogen gassing in all heating systems.
Giving the assurance of enhanced scale and corrosion protection, Sentinel RAPID-DOSE X100RD Inhibitor finds immense applications like maintaining pipework systems and similar other equipment. A few other application areas include:
- Boiler
- Heat Exchanger
- Radiators
- commercial and domestic LTHW systems
- Light commercial and HVAC heating and cooling systems
- Pumps
Sentinel X400 System Restorer - 5 gallon pail
Sentinel X400 High-Performance Heating System Restorer and Radiator Cleaner is specifically designed for cleaning older central heating systems. It is a non-acid treatment which restores circulation to radiators and pipework. It's ruthlessly efficient formula shifts built-up magnetite sludge, eliminating cold spots in radiators and restoring proper heat distribution. Use the Sentinel X100 to treat the system for limescale and corrosion.
KEY FEATURES
Sentinel X400 High-Performance Heating System Restorer and Radiator Cleaner is specifically designed for cleaning older central heating systems. It is a non-acid treatment which restores circulation to radiators and pipework. It's ruthlessly efficient formula shifts built-up magnetite sludge, eliminating cold spots in radiators and restoring proper heat distribution. Use the Sentinel X100 to treat the system for limescale and corrosion.
KEY FEATURES
- Restores systems suffering with circulation problems
- Eliminates radiator cold spots
- Prepares older systems for the installation of new components
- Has a non-acid formula which does not cause pin-holing or leaks
- Can be used in all types of indirect heating systems, including those containing aluminum
- Central Heating System Cleaner
- Aluminum Heating System Cleaner
- Residential Radiator Cleaner
- Indirect Heating System Cleaner
- Boiler System Cleaner
- Hydronic System Cleaner
- Magnetite Cleaner
Sentinel X400RD RAPID-DOSE High Performance Central Heating System Radiator Cleaner
Sentinel X400 High-Performance Cleaner is specifically designed for cleaning older central heating systems. It is a non-acid treatment which restores circulation to radiators and pipework. Its ruthlessly efficient formula shifts built-up magnetite sludge, eliminating cold spots in radiators and restoring proper heat distribution. Use the Sentinel X100RD to treat the system for limescale and corrosion.
KEY FEATURES
Sentinel X400 High-Performance Cleaner is specifically designed for cleaning older central heating systems. It is a non-acid treatment which restores circulation to radiators and pipework. Its ruthlessly efficient formula shifts built-up magnetite sludge, eliminating cold spots in radiators and restoring proper heat distribution. Use the Sentinel X100RD to treat the system for limescale and corrosion.
KEY FEATURES
- Restores systems suffering with circulation problems
- Eliminates radiator cold spots
- Prepares older systems for the installation of new components
- Has a non-acid formula which does not cause pin-holing or leaks
- Can be used in all types of indirect heating systems, including those containing aluminum
- Central Heating System Cleaner
- Aluminum Heating System Cleaner
- Residential Radiator Cleaner
- Indirect Heating System Cleaner
- Boiler System Cleaner
- Hydronic System Cleaner
- Magnetite Cleaner